Monitor Patient VitalCare
NIBP/ Pulse Rate w/o Printer
Criticare 506N3

 Monitor Patient VitalCare<br> NIBP/ Pulse Rate w/o Printer<br> Criticare 506N3
Monitor Patient VitalCare
NIBP/ Pulse Rate w/o Printer
Criticare 506N3
Item# Criticare-506N3
Regular price: $1,325.00
Sale price: $1,249.99

Product Description

 Monitor Patient VitalCare<br> NIBP/ Pulse Rate w/o Printer<br> Criticare 506N3
Monitor Patient VitalCare
NIBP/ Pulse Rate w/o Printer
Criticare 506N3

Share on facebook Share on twitter Share on email

Designed to travel everywhere you do, the VitalCareTM 506N3 series patient monitor with integrated carry-handle attaches quickly and easily to a rolling stand. Available in multiple configurations – with choice of Criticare or Nellcor oximetry – the 506N3 patient monitors provide maximum versatility and cost-effectiveness. New smart battery management allows up to 100 NIBP measurements on a single charging. With a compact design that is easily setup for spotcheck or continuous monitoring, the 506N3 patient monitor adapts readily to hospital, clinic and transport requirements.

Features and Benefits

Proprietary ComfortCuff ™ NIBP measures on inflation for faster, more comfortable readings. Choice of Criticare DOX™ digital SpO2 technology or Nellcor OxiMax™ SpO2 technology. Audible and visual alarms are adjustable providing instant notification the way you need them. Optional FILAC FasTemp™ predictive temperature for quick, accurate measurements. Optional internal printer for on-demand, automatic interval, trends or multi-patient reports.

Technical Specifications

Non-Invasive Blood Pressure

Technique: Oscillometric measure upon inflation Measurement Time: <40 seconds typical; 0 to 300mmHg; standard adult cuff Automatic Measurement Cycles: 1 - 60 minute; 2 - 4 hour; STAT Inflation Pressure Range: 30 to 300mmHg (Adult) 30 to 150mmHg (Pediatric) 20 to 150mmHg (Neonate) Resolution: 1mmHg Clinical Accuracy: SP-10:2002 Transducer Accuracy: ±2mmHg or ±2% of reading, whichever is greater, over full range STAT mode: 5 minutes of consecutive readings

Pulse Oximetry

Range: 1% to 99% Resolution: 1% Accuracy (DOX only): 70% to 99% range: ±2%; 50% to 69% range: ±3%; <50%: unspecified Accuracy (OxiMax Only): 70% to 99% range: ±2%; <70%: unspecified Method: Dual wavelength LED Audio: Tone with each detected pulse; pitch varies with saturation

Heart (Pulse) Rate

Range: 20 to 300bpm Accuracy (DOX only): Greater of ±1bpm or ±1%, of reading Unspecified for <30 or >240 bpm Accuracy (OxiMax only): Greater of ±1bpm or ±1%, of reading Unspecified for <30 or >240 bpm Update Time: Every second Resolution: 1bpm Pulse Volume: 10 levels or Off

Temperature (optional)

Type: FILAC FasTemp™ Method: Predictive or Continuous Channels: 1 Range: 30.0º to 43.0º C Accuracy Continuous Mode:±0.2°F (±0.1°C) Accuracy Predictive Mode: ±0.2°F (±0.1°C) for ranges 37°C to 39 °C (Compliant with EN 12470-3 and ASTM E1112:98) Resolution: 0.1º F or 0.1º C Predictive Response Time: Oral: 10 seconds typical; Axial: 10 seconds typical; Rectal: 10 seconds typical Probes/Wells: Oral/Axial FILAC FasTemp [202026] Rectal FILAC FasTemp (optional) [202034] Isolation Well, Oral, Axial [202089] Isolation Well, Rectal (optional) [202087]

Alarms

Indication: Audible; Visual Volume: 10 levels or Off Silence: Yes; 2 minutes or permanent

Trend Memory

Memory: Last 24 hours Parameters: SpO2, pulse rate, NIBP, temperature Report Types: Single Patient or Multi-patient; Selectable formats

Displays

Type: LED Parameters: NIBP, SpO2; temperature, pulse rate; pulse bar Status: Alarm Silence; Sensor; Low Battery; External Power; Patient Size Text: Alphanumeric LCD Languages: English, French, German, Italian, Portuguese, Spanish, Dutch, Danish

System Output

Com Port: Serial, RS 232-compatible

Printer

Type: Thermal array Tabular Mode: 1 - 60 minute intervals; 2 - 24 hour intervals; Auto on BP; Auto on Alarm, Off

Mechanical

Weight: Base unit with battery: 6.95 lb; 3.15kg Size: Base unit: 8.7" (H) x 7.1" (W) x 6.5” (D); 22cm (H) x 18cm (W) x 16.5cm (D)

Power Requirements

Voltage: 100 to 240 VAC, 50 to 60 Hz Battery: Sealed lead acid; Life: 8 hours Rechargeable: 6 hours

Environmental

Operating Temperature: 32º to 113º F; 0º to 45º C Storage Temperature: 23º to 122º F; -5º to 50º C Operating Humidity: 15% to 90%, non-condensing

Classification

Type of Protection: Class I equipment Degree of Protection: Type CF defibrillator-proof equipment Protection against Ingress: IPX1 rating, Drip-Proof Equipment