Monitor Patient VitalCare
NIBP/DOX/SpO2/Therm/ Pulse Printer
Criticare 506DNVP3

 Monitor Patient VitalCare <br>NIBP/DOX/SpO2/Therm/ Pulse Printer <br>Criticare 506DNVP3
Monitor Patient VitalCare
NIBP/DOX/SpO2/Therm/ Pulse Printer
Criticare 506DNVP3
Item# Criticare-506DNVP3
Regular price: $3,150.00
Sale price: $2,999.99

Product Description

 Monitor Patient VitalCare <br>NIBP/DOX/SpO2/Therm/ Pulse Printer <br>Criticare 506DNVP3
Monitor Patient VitalCare
NIBP/DOX/SpO2/Therm/ Pulse Printer
Criticare 506DNVP3

Designed to travel everywhere you do, the VitalCareTM 506NV3 series patient monitor with integrated carry-handle attaches quickly and easily to a rolling stand. Available in multiple configurations – with choice of Criticare or Nellcor oximetry – the 506NV3 patient monitors provide maximum versatility and cost-effectiveness. New smart battery management allows up to 100 NIBP measurements on a single charging. With a compact design that is easily setup for spotcheck or continuous monitoring, the 506NV3 patient monitor adapts readily to hospital, clinic and transport requirements.

NIBP, predictive Alaris TurboTemp® temperature—and exceptional ease of use make our 506NV3 series monitors the perfect solution to your clinical challenges. The 506NV3 TurboTemp® series is designed for facilities that are maintaining compatibility with IVAC type P850A probe covers and Alaris TurboTemp® probes. The lightweight 506NV3 monitor with integrated carry-handle attaches quickly and easily to IV pole mount or rolling stand. Available in configurations with or without internal printer, with optional CSI DOX™ or Nellcor OxiMax pulse oximetry—the 506NV3 series provides maximum versatility and cost-effectiveness.

Features and Benefits

Proprietary ComfortCuff ™ NIBP measures on inflation for faster, more comfortable readings. Choice of Criticare DOX™ digital SpO2 technology or Nellcor OxiMax™ SpO2 technology. Audible and visual alarms are adjustable providing instant notification the way you need them. Optional FILAC FasTemp™ predictive temperature for quick, accurate measurements. Optional internal printer for on-demand, automatic interval, trends or multi-patient reports.

Technical Specifications

Non-Invasive Blood Pressure

Technique: Oscillometric measure upon inflation. Measurement Time: <40 seconds typical; 0 to 300mmHg; Standard adult cuff. Automatic Measurement. Cycles: 1 - 60 minute; 2 - 4 hour; STAT. Inflation Pressure Range: 30 to 300mmHg (Adult) 30 to 150mmHg (Pediatric) 20 to 150mmHg (Neonate) Resolution: 1mmHg. Clinical Accuracy: SP-10:2002. Transducer Accuracy: ±2mmHg or ±2% of reading, whichever is greater, over full range. STAT mode: 5 minutes of consecutive readings.

Pulse Oximetry

Range: 1% to 99% Resolution: 1% Accuracy (DOX only): 70% to 99% range: ±2%; 50% to 69% range: ±3%; <50%: unspecified Accuracy (OxiMax Only): 70% to 99% range: ±2%; <70%: unspecified Method: Dual wavelength LED Audio: Tone with each detected pulse; pitch varies with saturation

Heart (Pulse) Rate

Range: 20 to 300bpm. Accuracy (DOX only): Greater of ±1bpm or ±1%, of reading. Unspecified for <30 or >240 bpm. Accuracy (OxiMax only): Greater of ±1bpm or ±1%, of reading. Unspecified for <30 or >240 bpm. Update Time: Every second. Resolution: 1bpm. Pulse Volume: 10 levels or Off.

Temperature (optional)

Type: Alaris TurboTemp®Method: Predictive or ContinuousChannels: 1 Predictive Mode Range: 96.0° to 106° F (35.6°> to 41.1°C) Continuous Mode Range: 80:0° to 106° F (26.7° to 41.1° C) Accuracy: ±0.2°F (±0.1°C) (measured in calibrated water bath in continuous mode) Resolution: 0.1° F or 0.1° C Response Time: 10 seconds typical (oral measurements) Probes: CAT1544 Oral, CAT 1545 Rectal Probe Covers: CAT 447 (P850A)

Alarms

Indication: Audible; Visual Volume: 10 levels or Off Silence: Yes; 2 minutes or permanent

Trend Memory

Memory: Last 24 hours Parameters: SpO2, pulse rate, NIBP, temperature Report Types: Single Patient or Multi-patient; Selectable formats

Displays

Type: LED Parameters: NIBP, SpO2; temperature, pulse rate; pulse bar Status: Alarm Silence; Sensor; Low Battery; External Power; Patient Size Text: Alphanumeric LCD Languages: English, French, German, Italian, Portuguese, Spanish, Dutch, Danish

System Output

Com Port: Serial, RS 232-compatible

Printer

Type: Thermal array Tabular Mode: 1 - 60 minute intervals; 2 - 24 hour intervals; Auto on BP; Auto on Alarm, Off

Mechanical

Weight: Base unit with battery: 6.95 lb; 3.15kg Size: Base unit: 8.7" (H) x 7.1" (W) x 6.5” (D); 22cm (H) x 18cm (W) x 16.5cm (D)

Power Requirements

Voltage: 100 to 240 VAC, 50 to 60 Hz Battery: Sealed lead acid; Life: 8 hours Rechargeable: 6 hours

Environmental

Operating Temperature: 32º to 113º F; 0º to 45º C Storage Temperature: 23º to 122º F; -5º to 50º C Operating Humidity: 15% to 90%, non-condensing

Classification

Type of Protection: Class I equipment Degree of Protection: Type CF defibrillator-proof equipment Protection against Ingress: IPX1 rating, Drip-Proof Equipment