INSIGHT Thoracic IT Film 30 x 35 cm , 100/Box Carestream 8147571
Product Description
INSIGHT Thoracic IT Film 30 x 35 cm , 100/Box Carestream 8147571
INSIGHT Thoracic Imaging Film
Capture low- and high-density anatomical structures in one exposure. INSIGHT Thoracic Imaging Film captures and displays a full range of contrast tones for low- and high-density anatomical structures?lung parenchyma to mediastinum?on a single sheet of film. Asymmetric emulsion/screen design provides a balance of exposure contrast levels that increase diagnostic confidence and decrease the amount of examinations, without compromising anatomical visualization.
INSIGHT thoracic imaging film is used in INSIGHT thoracic imaging systems to:
•Increase the quality and volume of information available for diagnosis
•Increase confidence for interpreting that information
•Decrease the number of repeat examinations
Zero-crossover film technology and asymmetric film emulsion/screen pairings allow these systems to capture two distinct images with one exposure.
•An image optimized to display lung parenchyma is captured on one side of the film.
•An image optimized to satisfy exposure parameters for mediastinum, retrocardiac, and sub-diaphragmatic anatomy is captured on the other side.
This asymmetric emulsion/screen design provides a full balance of exposure contrast levels (compared to conventional rare-earth film-screen combinations) without compromising anatomical visualization. On the viewbox, the two resultant images are perfectly aligned on one film due to excellent film-screen contact and strict manufacturing specifications.
INSIGHT thoracic imaging system
Standard contrast:
•INSIGHT thoracic imaging film
•INSIGHT thoracic imaging screens
•X-OMAT cassette
•Speed: 250 / mid-lung contrast: 1.40 / mediastinal contrast: 0.7
With the widest latitude, this system provides lower lung-field contrast and higher mediastinal contrast. This standard level of contrast may be preferred by radiologists accustomed to reading chest images with a very long grayscale.
High lung-field contrast:
•INSIGHT thoracic imaging film
•INSIGHT HC thoracic imaging screens
•X-OMAT cassette
•Speed: 335 / mid-lung contrast: 2.00 / mediastinal contrast: 0.5
This system provides higher lung-field and lower mediastinal contrast than the standard-contrast system described above. Overall system contrast is closest to the look of most conventional thoracic imaging systems.
Film storage
Store unopened boxes in a cool, dry place (50–75°F/10–23°C; 30–50% relative humidity) shielded from x-rays and other penetrating radiation.
Safelighting
Use safelight filter type GBX-2 or equivalent located at least 4 ft/1.2 m from the film.
Recommended processing
For best results, process film in X-OMAT and X-OMAT EX II chemicals